WARNING
Wear the necessary PPE for handling plant protection products (Safety instructions | Personal protective equipment (PPE)).
INFORMATION
The preparation of the spray mixture can be done in the designated mixing area or directly in the field.
-
Ensure the pump is turned off.
-
Fill the main tank with clear water, using the volume required to prepare a spray mixture for the entire treatment.
-
Add 200 L | 53 US gal of additional water for the final rinsing and 15 L | 4 US gal of water in the rinse tank in case of skin contact with products.
-
Wear the necessary PPE for handling products.
-
Set the valves in Mixture Prep: 1. Filling & Pre-mixing position mode.
Make sure Agitation1 and Agitation2 valves are closed.
INFORMATION
Do not use this 3D illustration as a reference. Please refer to the valve position modes table.
-
Reset the flow meter.
-
Engage the pump and transfer clear water to the mixture tank.
INFORMATION
The quantity is measured by the flow meter.
-
Add the required amount of product for the mixture.
-
Close the lid.
-
Set the valves to Mixture Prep: 2. Full Mixture Agitation position mode and agitate the mixture for 10 minutes in both zones (Agitation).
-
Switch the pump off.