Cleaning after treatment interruption for fluidic kit (optional)

INFORMATION

In case of treatment interruption:

  • Let the mixture sit for a maximum of 8 hours. After that, it is no longer usable.

  • Perform the Cleaning after treatment interruption procedure.


  1. Turn off the pump.

  1. Set the valves to Cleaning Sprayer position mode.

INFORMATION

Do not use this 3D illustration as a reference. Please refer to the valve position modes table.

fluidic-kit-stickers-valves.jpg
fluidic-kit_elements_general.png


  1. Engage the pump.

  2. Activate Flushing mode on the app.

  3. Spray approximately 100 L | 26 US gal on an untreated area.

  4. Turn off the pump.

  1. Remove and clean the suction filter (Cleaning).

suction-filter-fludic-kit.png
  1. If installed, remove and clean the section filter, located in the agitation tubing leading to Agitation1 and Agitation2 valves.

  2. Reassemble the filter(s) and check for leaks.

  3. When treatment is resumed, open Agitation1 and Agitation2 valves and agitate the mixture for 10 minutes (Agitation for fluidic kit (optional)).